Checks
These are the currently available checks
Reference ID
Name
Severity
Description & Solution
BP01
Inconsistent use of apply time series to result option
Best practice
Description: Formula Indicators within dashboard do not use the same setting for apply time series to result
Solution: Set the Formula Indicator option for apply time series to result consistently throughout the dashboard
ER01
Indicator breakdown missing
Error
Description: Indicator is used in a Formula Indicator but the added breakdowns are inconsistent. The Formula Indicator has breakdowns which are missing from the underlaying indicators
Solution: Add the missing breakdowns to the indicators used in Formula Indicator, make sure to (re)collect the scores for these breakdowns.
ER02
Indicator and collection job frequency mismatch
Error
Description: Automated Indicator collected in job where the indicator frequency is smaller than the job collection frequency. For example: a daily indicator is being collected monthly
Solution: Add the indicator to a collection job with the correct collection frequency.
ER03
Breakdown matrix option should be enabled for Automated Indicator
Error
Description: A breakdown dashboard has a breakdown widget (making it two levels of breakdowns), breakdown matrix option should be enabled for the Automated Indicator
Solution: Enable the breakdown matrix collection option for this Automated Indicator, make sure to exclude breakdowns which would return too many results.
ER04
Dashboard breakdown missing
Error
Description: Dashboard contains a breakdown that is not present in the included widget indicator while follow element for this widget is active
Solution: Add the missing breakdown to the indicator used in the widget or disable the follow element setting.
ER05
Formula Indicator missing references
Error
Description: Formula defined within the Formula Indicator has obsolete references
Solution: Fix the formula by applying the correct references.
ER06
Job collection error
Error
Description: The last collection run for this job resulted in an error, indicators included in this collection might have missing or incorrect data. This check includes all indicators, widgets and dashboards impacted by the collection error
Solution: Correct the error in collection job. Recollect the scores for indicators related to the collection job since the collection job is in state error.
ER07
Indicator has no Indicator Source
Error
Description: Automated Indicator has no Indicator Source
Solution: Link the automated indicator to the correct indicator source.
ER08
Breakdown excluded from collection job
Error
Description: Breakdown is used in a breakdown widget on a dashboard but the breakdown is excluded from the collection job
Solution: Include the breakdown in the collection job (or remove it from the exclusion list).
ER09
Widget follow element can be enabled
Error
Description: Dashboard contains a breakdown that is present in the included widget indicator while follow element for this widget is not active
Solution: Enable the follow element setting on the widget
IN01
Unused widget contains collected indicators
Orphaned elements
Description: Automated Indicator is actively collected but not being used (not linked to any widget present on a dashboard and not being used in a formula indicator)
Solution: Widget can be removed to clean up the platform or kept for later use if intended.
IN02
Unused widget without any collected indicator
Orphaned elements
Description: Formula indicator contains collected indicators and is not being used (not linked to any widget present on a dashboard and not being used in a formula indicator)
Solution: Widget can be removed to clean up the platform or kept for later use if intended.
IN03
Unused Breakdown Source
Orphaned elements
Description: Breakdown Source is not being used (not related to any breakdown that is mapped, not used by any breakdown and not used by any dashboard)
Solution:
IN04
Unused uncollected Automated Indicator
Orphaned elements
Description: Collection job has no related indicators
Solution:
IN05
Unused collected Automated Indicator
Orphaned elements
Description: Formula indicator contains uncollected indicators and is not being used (not linked to any widget present on a dashboard and not being used in a formula indicator)
Solution:
IN06
Unused Formula Indicator contains collected indicators
Orphaned elements
Description: Widget is not used on any dashboard and without any collected indicator
Solution:
IN07
Unused Formula Indicator contains uncollected indicators
Orphaned elements
Description: Widget is not used on any dashboard and contains collected indicator(s)
Solution: Indicator can removed or kept for later use if intended.
IN08
Collection job has no related indicators
Orphaned elements
Description: Automated Indicator is not collected and being used (not linked to any widget present on a dashboard and not being used in a formula indicator)
Solution:
WA01
Indicator collected in multiple jobs
Warning
Description: Indicator is being collected in more than one active collection job
Solution: Indicator should only be collected in one active collection job.
WA02
Automated Indicator used on a dashboard is not being collected
Warning
Description: Automated Indicator used on a dashboard is not scheduled in any active collection job
Solution: Add the Automated Indicator to an active collection job.
WA03
Formula Indicator used on a dashboard contains uncollected indicators
Warning
Description: Formula Indicator used on a dashboard contains Automated Indicators which are not scheduled in any active collection job
Solution: Add the Automated Indicator used in the formula to an active collection job.
WA04
Heatmap widget excessive breakdown count
Warning
Description: The breakdown count for the second level breakdown calculations could possibly result in the widget not functioning correctly.
Solution:
WA05
Widget average loading time exceeds threshold
Warning
Description: The average loading time of the widget has exceeded the threshold
Solution: